Add to Cart
At NEWBASE, we specialize in the production of advanced Battery Thermal Management Systems (BTMS) for fully electric commercial vehicles. Our water-cooled units are a crucial component of the BTMS, designed to maintain the battery's internal temperature within its optimal operating range. This minimizes the temperature difference between the highest and lowest points inside the battery box, ensuring stable battery performance and extending the overall lifespan of the battery.
Unit Model | NBSLJZ-03-01 |
Rated cooling capacity (kw) | 3.5 |
Low-voltage power demand | 450W |
High voltage power supply | DC400V-DC750V |
Low voltage power supply | DC24V(18V-32V) |
Built in water pump | >20L/min @110 KPa |
Control power supply | DC24V battery provides on/off signal |
Protection level | IPX7 |
Refrigerant | R134a |
Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
Dimensions | 530(L)*446(W)*365(H) |
Unit fixed point | Φ12 holes *4 |
Joint | Inlet and outlet water pipeΦ25 |
Connector | can be configured according to customer needs |
Low voltage power | 24V 450W |
Unit Model | NBSLJZ-05-01 |
Rated cooling capacity (kw) | 5 |
Heating capacity | 6-14kw(Optional) |
High voltage power supply | Rated voltage 320VDC (220~450 VDC) |
Low voltage power supply | DC24V(18V-32V) |
Built in water pump | 11m&1800l/h |
Control power supply | DC24V battery provides on/off signal |
Protection level | IPX7 |
Refrigerant | R134a |
Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
Dimensions | 635(L)*530(W)*380(H) |
Unit fixed point | 569mm*369mm Φ12holes *4 |
Joint | Inlet and outlet water pipeΦ25 |
Connector | can be configured according to customer needs |
Low voltage power | 24V 600W |
Unit Model | NBSLJZ-08-01 |
Rated cooling capacity (kw) | 8 |
Low-voltage power demand | 600W |
High voltage power supply | DC400V-DC750 |
Built in water pump | 20m&2000l/h |
Control power supply | DC24V battery provides on/off signal |
Protection level | IPX7 |
Refrigerant | 134a/R407C |
Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
Dimensions | 820(L)*575(W)*285(H) |
Unit fixed point | 495mm*320mm Φ12holes *6 |
Joint | Inlet and outlet water pipeΦ25(Reserved overflow pipeΦ8) |
Connector | can be configured according to customer needs |
Electronic control | Four in one/Three in one integrated |
Unit Model | NBSLJZ-10-01 |
Rated cooling capacity(kw) | 10 |
Heating capacity | 24KW(Optional) |
High voltage power supply | 640VDC (400~750 VDC) |
Built in water pump | 17.5m&2880l/h |
Control power supply | DC24V battery provides on/off signal |
Protection level | IPX7 |
Refrigerant | 134a |
Type of secondary refrigerant | 50%VV Ethylene glycol aqueous solution |
Dimensions | 960(L)*603(W)*291(H) |
Unit fixed point | 521mm*320mm Φ12holes *6 |
Joint | Inlet and outlet water pipeΦ25(Reserved overflow pipeΦ8) |
Connector | can be configured according to customer needs |
Electronic control | Four in one/Three in one integrated |
Unit Model | NBSLJZ-13-01 |
Rated cooling capacity (kw) | 12 |
Heating capacity(kw) | Optional24Kw-30Kw |
High voltage power supply | DC400V-DC750V |
Low voltage power supply range | DC 18~32V |
Energy efficiency ratio | 2.0 |
Protection level | IPX7 |
Refrigerant | 134a/R407C |
Type of secondary refrigerant | 50%/50% Ethylene glycol aqueous solution |
Dimensions | L1370×W1030×H285 mm |
Unit fixed point | Φ12holes *8 |
Joint | Inlet and outlet water pipeΦ25 |
Connector | can be configured according to customer needs |
Electronic control | Four in one/Three in one integrated |